83−11. 438 0. 585 8 in.2
0. 6FyAgv UbsFuAnt 0. 63610. 881. 0580. 5858269. 0 kips
Rn0. 75269. 0201. 8 kips 220 kips (N.G.)
Try ℓe3 in. and s41
2in.
0. 6FyAgv UbsFuAnt 0. 63612. 381. 0580. 5858301. 4 kips
Rn0. 75301. 4226. 1 kips 220 kips (OK)
Use an L8 65
145. 3 kips
Combination 2 controls; use Pa150 kips. Slip-critical strength will control over
shear. Use the following spreadsheet table to help select the number of bolts.
[7-21]
© 2018 Cengage Learning®. All Rights Reserved. May not be scanned, copied or duplicated,
or posted to a publicly accessible website, in whole or in part.
0. 5Fu
0. 5585. 17 in.2
Required rmin L
300 20 12
300 0. 80 in.
Try L8 65
8
43. 334 in. Use 4 in.
Minimum edge distance from AISC Table J3.4 15
8in. Use 2 1
2in. Check
bearing:
Inner bolts: From Manual Table 7-4 and a spacing of 2 2
818. 5 −4. 51. 438 29. 022 in.2
Ant 3
83−11. 438 0. 585 8 in.2
From AISC Equation J4-5,
Rn0. 6FuAnv UbsFuAnt
0. 6FyAgv UbsFuAnt 0. 63613. 881. 0580. 5858333. 8 kips
Rn
333. 8
2. 00 167 kips Pa150 kips (OK)
7.7-3
(a) LRFD Solution: Pu1. 2D1. 6L1. 2451. 6105222. 0 kips
43. 39 5. 116 try 6 bolts in two rows.
Select a tension member. Required AgPu
0. 9Fy
222
0. 9366. 85 in.2
0. 75Fu
0. 75585. 10 in.2
Required rmin L
300 15 12
300 0. 6 in.
Try 2L7 47
16 LLBB
0. 6FyAgv UbsFuAnt 0. 6368. 251. 0580. 6326214. 9 kips
The nominal block shear strength of the gusset plate is therefore 203.8 kips
The design block shear strength is Rn0. 75203. 8
152. 9 kips Pu220 kips (N.G.)
0. 6FyAgv UbsFuAnt 0. 63612. 751. 0580. 6326312. 1 kips
The nominal block shear strength of the gusset plate is therefore 312.1 kips
The design block shear strength is Rn0. 75312. 1234 kips Pu220 kips
(OK)
0. 6Fy
0. 6366. 94 in.2
Required AePa
0. 5Fu
150
0. 5585. 17 in.2
Required rmin L
300 15 12
300 0. 6 in.
Try 2L7 47
16 LLBB
2 1/2"
2" 3 sp. @ 3" 2"
0. 6FyAgv UbsFuAnt 0. 6368. 251. 0580. 6326214. 9 kips
The nominal block shear strength of the gusset plate is therefore 214.9 kips
[7-27]
© 2018 Cengage Learning®. All Rights Reserved. May not be scanned, copied or duplicated,
or posted to a publicly accessible website, in whole or in part.
The allowable block shear strength is
Rn
0. 6FyAgv UbsFuAnt 0. 63612. 751. 0580. 6326312 kips
The nominal block shear strength of the gusset plate is therefore 312 kips
The allowable block shear strength is
Rn
7.8-1
b5. 5 −tw
1. 25b1. 252. 4583. 073 in. 2.45 in. ∴use a2.45 in.
[7-28]
© 2018 Cengage Learning®. All Rights Reserved. May not be scanned, copied or duplicated,
or posted to a publicly accessible website, in whole or in part.
b´b−d
22. 458 −3/4
22. 083 in.
a´ad
1−B
T−1a´
b´
0. 73751−0. 19281. 3560. 479 9 1. 0
Required tf4Tb´
bpFu14252. 083
0. 903. 3336510. 73750. 4799
BcT1
1b´
a´25 1 0. 1011
10. 10112. 083
2. 825
26. 7 kips Rn29. 82 kips (OK)
Connection is adequate. Required tf0. 888 in. 0.985 in.
[7-29]
© 2018 Cengage Learning®. All Rights Reserved. May not be scanned, copied or duplicated,
or posted to a publicly accessible website, in whole or in part.
BcT1
7.8-2
For b, use the distance from the bolt centerline to the mid-thickness of the angle leg.
1. 25b1. 252. 1882. 735 in. 1.5 in. ∴use a1.5 in.
b´b−d
22. 188 −1/2
21. 938 in.
[7-30]
© 2018 Cengage Learning®. All Rights Reserved. May not be scanned, copied or duplicated,
or posted to a publicly accessible website, in whole or in part.
a´ad
1−B
T−1a´
b´
0. 82141−0. 69870. 90302. 081 1. 0
∴use 1. 0
Required tf4Tb´
0. 821400
BcT1
1b´
a´7. 8 1 0
101. 938
1. 75
7. 8 kips Rn13. 25 kips (OK)
Connection is adequate. Required tf0. 426 in. 5/8 in.
1−B/T−1a′/b′0. 682 70. 9030
0. 82141−0. 682 70. 9030 1. 96 1. 0
∴use 1. 0
From Equation 7.19,
Required tfb4Tb′
pFu11. 6745. 251. 938
3. 55810. 82141. 0
ptf
2Fu
0. 8214
3. 55/8258−1−0. 174 0
Since must be between 0 and 1 inclusive, use 0
7.9-1
Nominal shear strength (assume that the threads are in shear):
Abd2
2. 4dtFu2. 47/80. 6406587. 36 kips
2. 4dtFu87. 36 kips 103.0 kips ∴use Rn87. 36 kips
(a) LRFD solution
Pu1. 2D1. 6L1. 2841. 666206. 4 kips
TuTensile force 206. 4 cos 30 ° 178. 7 kips, or 178. 7
Fnt
0. 755421. 4569. 33 ksi 90 ksi
RnFnt
′Ab0. 7569. 330. 601331. 3 kips/bolt 22. 3 kips/bolt (OK)
The connection is adequate.
(b) ASD solution
Fnv
0. 6013 15. 59 ksi
Fnt
′1. 390−2. 0090
7.9-2
Nominal shear strength:
Abd2
43/42
40. 441 8 in.2
RnFnvAb540. 441823. 86 kips/bolt
Fnt
0. 755424. 9761. 51 ksi 90 ksi
RnFnt
′Ab0. 7561. 510. 441820. 4 kips/bolt 22.1 kips/bolt (N.G.)
5
44. 72
67. 453 kips/bolt
The allowable shear strength is Rn
Fnv
0. 4418 16. 87 ksi
Fnt
′1. 390−2. 0090
7.9-3
(a) LRFD solution
Pu1. 2D1. 6L1. 2201. 660120. 0 kips
0. 7554frv 117. 0 −2. 222 frv ≤90
[7-35]
© 2018 Cengage Learning®. All Rights Reserved. May not be scanned, copied or duplicated,
or posted to a publicly accessible website, in whole or in part.
Fnt
′0. 75117 −2. 222frv≤0. 759087. 75 −1. 667frv ≤67. 5
′72
Ab
0. 6013 4. 397, Try 6 bolts for symmetry.
First, check the upper limit on Fnt
′:
frv 96
Ab
96
60. 601326. 61 ksi
′117 −2. 222frv 117 −2. 22226. 6157. 87 ksi 90 ksi (OK)
Assume that tension controls:
Fnt
′1. 3Fnt −Fnt
Fnv
frv ≤Fnt
1. 390−2. 0090
54 frv ≤90 117 −3. 333frv ≤90
Fnt
′
Ab
0. 6013 4. 397
Try six bolts for symmetry. First, check the upper limit on Fnt
′:
2. 4dtFu
7.9-4
(a) LRFD solution
Tension member-to-gusset plate connection:
Pu1. 2D1. 6L1. 20. 25 1201. 60. 75 120180 kips
Bolt shear strength:
Gusset plate-to-column angles connection:
Bearing on the angles will control, because 2 3
8in. 7
8in.
Rn2. 4dtFu0. 752. 47/823
85868. 5 kips/bolt
1. 1349nb
1. 1349nbnb
127. 3 nb33. 22 −76. 37
nb
33. 22nb−76. 37 nb6. 13
Use 6 rows of 2 bolts for symmetry and to match the arrangement of gusset
plate-to-connection angle bolts. Check tension.
Shear/tension load per bolt 127. 3/12 10. 61 kips
81
16 0. 937 5 in.
[7-38]
© 2018 Cengage Learning®. All Rights Reserved. May not be scanned, copied or duplicated,
or posted to a publicly accessible website, in whole or in part.
For the hole nearest the edge, ℓcℓ
e−h
21. 5 −0. 9375
21. 031 in.
2. 4dtFu0. 752. 47/87/85879. 9 kips/bolt
For the other bolts,
Rn1. 2ℓctFu0. 751. 21. 5637/85871. 4 kips 30 kips (OK)
For the gusset plate-to-column connection angles,
Rn23/8
Bolt shear strength:
Abd2/4 7/82/4 0. 601 3 in. 2
Rn
1
FnvAb1
2. 00 680. 60132 shear planes 40. 89 kips/bolt
Check bearing on the gusset plate assuming bearing deformation strength controls.
[7-39]
© 2018 Cengage Learning®. All Rights Reserved. May not be scanned, copied or duplicated,
or posted to a publicly accessible website, in whole or in part.
Rn
connection, ∴use 6 bolts.
Connection angles-to-column flange connection: assume that the slip-critical strength
will control. Select the number of bolts based on slip-critical strength, then check
tension.
TaVa1
1. 1349nb
Use 6 rows of 2 bolts for symmetry and to match the arrangement of gusset
plate-to-connection angle bolts. Check tension.
Shear/tension load per bolt 84. 85/12 7. 07 kips