page-pf1
383)
383)
The coil of a potential relay used with small single-phase compressors should have a resistance of
approximately:
A)
1 .
B)
50 .
C)
10,000 .
D)
250 .
Answer:
C
Explanation:
A)
B)
C)
D)
384)
384)
Select the code requirements when a unit is located in an attic. You may select more than one.
A 30-in-deep service area in front of the service panel
A 24-in-wide plywood platform from the access to the unit
A pocket or folder to hold the manufacturer's literature
A light near the unit
A maximum of 20 ft from the access to the unit
A 22" × 30' access hole
An adjustable air register by the equipment for the technician
A light switch by the access door
Answer:
A, B, D, E, F, H
Explanation:
A)
B)
C)
D)
E)
F)
G)
H)
385)
385)
How is the water flow in a hydronic heating system checked?
A)
By measuring the amp draw of the pump motor and applying the formula gp = amps × 1.73
B)
By measuring the pressure drop across the water pump and comparing it to a pumping
performance chart
C)
By measuring the impeller RPM using a stroboscope
D)
By measuring the pump motor RPM using a digital tachometer
Answer:
B
Explanation:
A)
B)
C)
D)
100
page-pf2
386)
386)
Which manufacturer-supplied reference uses pass/fail tests to guide the technician to the possible
cause of system malfunction?
A)
The symptoms list
B)
The logic flowchart
C)
The fault code reference list
D)
The benchmark data
Answer:
B
Explanation:
A)
B)
C)
D)
387)
387)
What is the best way to warm a refrigerant cylinder?
A)
With a torch
B)
In a bucket of warm water
C)
Over a hot flame
D)
By pouring boiling water over the cylinder
Answer:
B
Explanation:
A)
B)
C)
D)
388)
388)
What side of an air-conditioning coil generally collects dirt?
A)
The side where air exits the coil
B)
Both sides build up dirt equally.
C)
Dirt will not build up on an air-conditioning evaporator coil.
D)
The side where air enters the coil
Answer:
D
Explanation:
A)
B)
C)
D)
389)
389)
The contactor on most residential split-system condensing units controls:
A)
The compressor.
B)
The condenser fan motor.
C)
The compressor, condenser fan motor, and evaporator fan motor.
D)
The compressor and the condenser fan motor.
Answer:
D
Explanation:
A)
B)
C)
D)
101
page-pf3
390)
390)
To safely increase the pressure in a refrigerant cylinder while charging a system, the technician
should:
A)
Run warm water over the cylinder.
B)
Heat the top of the cylinder with a small propane torch.
C)
Immerse the cylinder in a tub of boiling water.
D)
Heat the bottom of the cylinder with a small propane torch.
Answer:
A
Explanation:
A)
B)
C)
D)
391)
391)
A technician needs to check the heating operation of a heat pump that has no gauge access ports.
The technician should start by:
A)
Installing bolt-on piercing valves on both the gas line and the liquid line.
B)
Recovering the system refrigerant using piercing pliers and installing permanent braze-on
service valves.
C)
Checking the temperature rise across the indoor coil.
D)
Installing bolt-on piercing valves on both the high side and low side of the compressor.
Answer:
C
Explanation:
A)
B)
C)
D)
392)
392)
What should the service technician do if a blown fuse is found in the unit disconnect switch
during the preliminary inspection?
A)
Replace the fuse with one a size larger to prevent nuisance problems.
B)
Replace the fuse with a copper pipe, turn the disconnect on, and check the wire to see if it is
getting warm.
C)
Replace the fuse with one of the same size and turn the disconnect switch back on.
D)
Check all major loads for shorts and grounds.
Answer:
D
Explanation:
A)
B)
C)
D)
102
page-pf4
393)
393)
Why should the temperature inside the compressor be kept under 300°F?
A)
Because the compressor oil starts to break down above 300°F
B)
Because the metal components inside the compressor will start to melt
C)
Because the refrigerant starts to fractionate above 300°F
D)
Because the refrigerant starts to boil inside the compressor above 300°F
Answer:
A
Explanation:
A)
B)
C)
D)
394)
394)
As an operational safety check, what should be checked in the combustion gases for combustion
appliances?
A)
Carbon monoxide levels
B)
Nitrogen levels
C)
Oxygen levels
D)
Carbon dioxide levels
Answer:
A
Explanation:
A)
B)
C)
D)
395)
395)
The diagnostic board on a system is flashing three short flashes, pausing, and then flashing two
long flashes. This most likely is displaying:
A)
The dateMarch 2.
B)
The suction pressure32 psig.
C)
A secret code known only to the designer. Manufacturers do not share their fault codes with
service technicians.
D)
Fault code 32.
Answer:
D
Explanation:
A)
B)
C)
D)
396)
396)
After a capacitor is discharged:
A)
It may be exchanged for a charged capacitor for a nominal fee.
B)
It may be reused if it is first charged with a capacitor charger.
C)
It is safe to handle.
D)
It is no longer useful and must be replaced.
Answer:
C
Explanation:
A)
B)
C)
D)
103
page-pf5
397)
397)
With the system operating, a technician gets a reading of 20 V between the L1 and T1 terminals at
the contacts of the contactor. This tells the technician that:
A)
The contacts are defective because they have a measurable voltage drop.
B)
The contactor is operating correctly.
C)
The compressor is defective.
D)
The transformer is defective because the voltage should be 24 V.
Answer:
A
Explanation:
A)
B)
C)
D)
398)
398)
When troubleshooting an induced-draft gas furnace, what should be checked if the induced-draft
fan comes on but the igniter is never energized?
A)
Check the control transformer.
B)
Check the microamp signal of the flame sensor.
C)
Check the incoming gas pressure.
D)
Check the draft pressure switch to see if it is closed.
Answer:
D
Explanation:
A)
B)
C)
D)
399)
399)
To check the condition of the compressor's motor windings, a technician will need to measure the
resistance of the windings using a standard:
A)
Ammeter.
B)
Multimeter.
C)
Ohmmeter.
D)
Voltmeter.
Answer:
C
Explanation:
A)
B)
C)
D)
400)
400)
The portion of a planned maintenance call in which worn parts are replaced, filters are changed,
and needed adjustments are made is referred to as:
A)
Troubleshooting.
B)
The precheck.
C)
Routine maintenance.
D)
Operational testing.
Answer:
C
Explanation:
A)
B)
C)
D)
104
page-pf6
401)
401)
Before checking the switches in the circuit to a nonfunctioning load, the technician should first
check:
A)
The resistance of the nonfunctioning device.
B)
Line voltage, control voltage, and voltage to the nonfunctional component.
C)
The current draw of the nonfunctioning device.
D)
The resistance of all the devices in the same circuit with the nonfunctional device.
Answer:
B
Explanation:
A)
B)
C)
D)
402)
402)
A hot compressor with an infinite ohms reading between common and the other two terminals
and a reading of 4.3 between the start and run terminals most likely has:
A)
An open start winding.
B)
An open internal overload.
C)
A shorted run winding.
D)
An open common winding.
Answer:
B
Explanation:
A)
B)
C)
D)
403)
403)
The air filter should be checked:
A)
After completion of the service call.
B)
When testing to isolate the cause of the system malfunction.
C)
While collecting operational data.
D)
During the preliminary inspection.
Answer:
D
Explanation:
A)
B)
C)
D)
404)
404)
Many technicians use a(n) ________ to measure all electrical characteristics.
A)
multimeter
B)
ammeter
C)
voltmeter
D)
ohmmeter
Answer:
A
Explanation:
A)
B)
C)
D)
105
page-pf7
405)
405)
Once you have isolated the root cause of the malfunction, you may:
A)
Bill the customer.
B)
Recommend corrective action.
C)
Replace the malfunctioning part.
D)
Collect operational data.
Answer:
B
Explanation:
A)
B)
C)
D)
406)
406)
The first step in troubleshooting a system is:
A)
Understanding the system operational sequence.
B)
Replacing defective components.
C)
Recognizing what component is operating incorrectly.
D)
Testing to isolate the cause.
Answer:
A
Explanation:
A)
B)
C)
D)
MATCHING. Choose the item in column 2 that best matches each item in column 1.
Match the system characteristics to the types of heat reclaim system.
407)
Refrigerant travels through the
reclaim coil before going to the
condenser
Answer:
C
408)
Uses a secondary glycol loop
Answer:
A
409)
Recovers both sensible and latent
heat
Answer:
B
A)
hydronic
B)
parallel
C)
series
407)
408)
409)
Match the rack system components with their functions.
410)
Indicates liquid level in receiver
Answer:
A
A)
liquid level sensor
410)
106
page-pf8
411)
Removes oil from discharge gas
Answer:
B
412)
Filters out moisture and particulates
Answer:
A
413)
Reduces flash gas in the liquid line
Answer:
C
A)
liquid line dryer
B)
oil separator
C)
subcooler
411)
412)
413)
107
page-pf9
Answer Key
Testname: UNIT 81 TO 92
1)
B
2)
B
3)
D
4)
B
5)
D
6)
D
7)
A
8)
A
9)
C
10)
A
11)
D
12)
D
13)
A
14)
A
15)
C
16)
B
17)
D
18)
A
19)
B
20)
B
21)
D
22)
B
23)
D
24)
C
25)
A
26)
B
27)
D
28)
A
29)
D
30)
D
31)
C
32)
D
33)
B
34)
A
35)
B
36)
A
37)
A
38)
C
39)
D
40)
A
41)
C
42)
B
108
page-pfa
Answer Key
Testname: UNIT 81 TO 92
43)
A
44)
C
45)
C
46)
A
47)
C
48)
B
49)
B
50)
B
51)
C
52)
D
53)
B
54)
C
55)
D
56)
B
57)
C
58)
A
59)
D
60)
A
61)
C
62)
C
63)
C
64)
B
65)
B
66)
B
67)
B
68)
B
69)
A
70)
C
71)
A
72)
B
73)
B
74)
B
75)
C
76)
B
77)
A
78)
B
79)
B
80)
B
81)
D
82)
C
83)
D
84)
C
109
page-pfb
Answer Key
Testname: UNIT 81 TO 92
85)
C
86)
B
87)
D
88)
A
89)
B
90)
B
91)
B
92)
B
93)
D
94)
A
95)
D
96)
B
97)
C
98)
C
99)
B
100)
A
101)
C
102)
C
103)
D
104)
B
105)
A
106)
B
107)
B
108)
B
109)
C
110)
B
111)
C
112)
B
113)
B
114)
D
115)
B
116)
C
117)
A
118)
B
119)
D
120)
A
121)
A
122)
C
123)
C
124)
C
125)
A
126)
C
110
page-pfc
Answer Key
Testname: UNIT 81 TO 92
127)
D
128)
C
129)
A
130)
D
131)
A
132)
D
133)
A
134)
C
135)
C
136)
A
137)
D
138)
C
139)
B
140)
D
141)
C
142)
C
143)
B
144)
A
145)
B
146)
D
147)
A
148)
B
149)
D
150)
C
151)
A
152)
B
153)
C
154)
C
155)
A
156)
A
157)
D
158)
D
159)
B
160)
B, C, E
161)
D
162)
D
163)
A
164)
B
165)
A
166)
A
167)
B
168)
C, E, F
111
page-pfd
Answer Key
Testname: UNIT 81 TO 92
169)
B
170)
B, C, E
171)
D
172)
D
173)
C
174)
A
175)
D
176)
C
177)
A
178)
C
179)
C
180)
B, D, E, F
181)
B
182)
C
183)
C
184)
B
185)
B
186)
B
187)
D
188)
C
189)
B
190)
C, E, F
191)
B
192)
A
193)
B
194)
C
195)
A
196)
A
197)
B
198)
A
199)
A
200)
D
201)
B
202)
B
203)
A
204)
D
205)
A
206)
B
207)
D
208)
D
209)
B
210)
B
112
page-pfe
Answer Key
Testname: UNIT 81 TO 92
211)
D
212)
D
213)
B
214)
C
215)
A
216)
B
217)
B
218)
B
219)
A
220)
C
221)
B
222)
A
223)
C
224)
C
225)
C
226)
D
227)
B
228)
D
229)
C
230)
C
231)
D
232)
C
233)
A
234)
C
235)
B
236)
C
237)
A
238)
D
239)
C
240)
A, E
241)
C
242)
B, E, F
243)
D
244)
C
245)
D
246)
C
247)
A
248)
C
249)
C
250)
A
251)
B
252)
D
113
page-pff
Answer Key
Testname: UNIT 81 TO 92
253)
A
254)
D
255)
C
256)
B
257)
B
258)
A
259)
B
260)
A
261)
B
262)
D
263)
C
264)
D
265)
D
266)
C
267)
C
268)
A
269)
C
270)
A
271)
D
272)
A
273)
C
274)
A
275)
C
276)
D
277)
A
278)
D
279)
A
280)
D
281)
A
282)
D
283)
C
284)
A
285)
B
286)
B
287)
C
288)
A
289)
D
290)
C
291)
D
292)
B
293)
C
294)
A, C, F
114
page-pf10
Answer Key
Testname: UNIT 81 TO 92
295)
D
296)
D
297)
A
298)
C
299)
D
300)
C
301)
C
302)
D
303)
D
304)
B
305)
C
306)
A
307)
D
308)
C
309)
A
310)
B
311)
D
312)
B
313)
B
314)
B
315)
C
316)
C
317)
C
318)
D
319)
C
320)
C
321)
A
322)
A, D, E
323)
B
324)
C
325)
B
326)
A
327)
D
328)
A, C
329)
C
330)
B
331)
C
332)
D
333)
A
334)
B
335)
B
336)
D
115
page-pf11
Answer Key
Testname: UNIT 81 TO 92
337)
A
338)
C
339)
A
340)
D
341)
D
342)
C
343)
A
344)
A
345)
D
346)
A, D, E
347)
D
348)
C
349)
C
350)
A
351)
B
352)
A
353)
B
354)
D
355)
C
356)
D
357)
C
358)
C
359)
B
360)
C
361)
A
362)
B
363)
A
364)
B
365)
A
366)
C
367)
A
368)
D
369)
A
370)
D
371)
A
372)
A
373)
B
374)
B, C, D, E, G
375)
C
376)
D
377)
A, C, D, F, G
378)
D
116
page-pf12
Answer Key
Testname: UNIT 81 TO 92
379)
C
380)
C
381)
B
382)
C
383)
C
384)
A, B, D, E, F, H
385)
B
386)
B
387)
B
388)
D
389)
D
390)
A
391)
C
392)
D
393)
A
394)
A
395)
D
396)
C
397)
A
398)
D
399)
C
400)
C
401)
B
402)
B
403)
D
404)
A
405)
B
406)
A
407)
C
408)
A
409)
B
410)
A
411)
B
412)
A
413)
C
117

Trusted by Thousands of
Students

Here are what students say about us.

Copyright ©2022 All rights reserved. | CoursePaper is not sponsored or endorsed by any college or university.